EAN code8595057626287
Customs code39174000
Weight0,0210 kg/pcs
Colourblack
MaterialPC-ABS
Halogen free materialyes
UV stable/UV stable materialyes
Self-extinguishing30 s
Temperature resistance-45 - 90 °C
Mechanical protectionIK09
Length70 mm
Pipe outside diameter32 mm
Funcionality in fireP90-R, E90, PS90
Area with explosion danger
Can be installed in a zone with the danger of explosion of flammable gases and vapors of zone 2 and into the zone of danger of explosion of flammable dusts of zone 22.
Fire reaction class of underlying materialA1 - F
StandardsČSN EN 61386-1 ed.2
Fire resistance standardsČSN 73 0895, DIN 4102-12, STN 92 0205
For pipes32

The connectors are designed to join pipes. Socketing of pipes and elbows reduces the consumption of connectors when making rigid pipe installations.

Note for system with maintained functionality in fire:
You find more information in the catalogue Systems with maintained functionality in fire.